Get in touch with DEMIKS Company
DJF Series · IEC 60270:2000
Partial Discharge Tester: 1-to-4 Channel Digital PD Detectors & HV Test Systems
Shanghai DEMIKS Electric Power Technology Co., LTD builds digital partial discharge testers and PD-free high-voltage test systems. Each electrical partial discharge tester measures picocoulomb (pC) apparent charge in transformers, power cables, switchgear, and motors. Send your specimen voltage and capacitance to receive an itemized engineering quote within 24 hours.
- Engineer-reviewed quote within 24 hours
- Benchtop instruments ship in 7–15 working days
- 0.1 pC sensitivity per IEC 60270:2000
- 1 set minimum order quantity (MOQ)
Applications Direct circuit review for FATs, OEM test bays, and Substation commissioning crews.
Deliverables Every partial discharge measurement unit ships with an ex-factory inspection report, certificate of conformity, English operation manual, and 12-month warranty card.
Digital Partial Discharge Tester Capabilities at a Glance
Our offline partial discharge test equipment employs multi-channel digital pulse capture with low-noise AC excitation up to 1000 kV. Verified operating limits of the DJF instrument series are shown below.
Signal Acquisition
- Channel Architecture: 1-to-4 synchronous channels (DJF-126, DJF-124, DJF-125, DJF-127)
- Apparent Charge Range: 0.1 pC sensitivity; 0.1 pC to 100,000 pC (up to 10,000 nC on PDIV cabin)
- Digitizer & Filter: 12-bit ADC at 1 / 5 / 10 MHz; 10 kHz to 1 MHz digital bandpass
- Specimen Capacitance: 6 pF to 250 µF across bushings, transformers, cables, and stator coils
HV Source & Delivery
- System Noise Floor: ≤5 pC rated-voltage background noise; ≤10% nonlinear error
- Matched HV Sources: 1 kVA to 1000 kVA, AC 0 to 1000 kV oil-immersed and SF6 PD-free transformers
- Standard Lead Time: 7–15 working days benchtop; 20–30 working days custom HV systems
- Order & Export Support: 1 set MOQ; exported to 8 countries with paid on-site commissioning
Digital Partial Discharge Detector & Analyzer Model Lineup
Offline IEC 60270 benchtop analyzers and handheld ultrasonic, TEV, or UHF spot sensors serve distinct diagnostic roles. Handheld acoustic cameras screen live switchgear for surface corona without picocoulomb calibration. Factory acceptance contracts require calibrated readings of apparent charge value in pC under controlled AC overvoltage.
DJF-126 Four-Channel Benchtop Digital PD Tester
The DJF-126 4-channel benchtop digital partial discharge tester delivers 0.1 pC sensitivity across a 0.1 pC to 100,000 pC range. Its 12-bit digitizer runs at selectable 1 MHz / 5 MHz / 10 MHz sampling rates with a 10 kHz to 1 MHz digital filter. Six gain gears (-40 dB to 60 dB) and 50–500 Hz sync cover 6 pF to 250 µF specimens.
DJF-124, DJF-124NT & DJF-127 Touchscreen PD Detectors
DJF-124, DJF-124NT, and DJF-127 digital partial discharge detectors replace CRT oscilloscope tubes and physical knobs with a 10.1-inch touch screen. Nine selectable frequency-band combinations and hardware-plus-software anti-interference filtering suppress VFD noise where background interference signals often exceed the acceptance level. Direct calibrated pC pulse readout pairs with an independent accumulation timer.
DJF-125 & 124T PD Meters with Industrial PC Control
Systems pairing DJF-125 or 124T partial discharge meters with industrial embedded-PC control support automated high-voltage testing. The control package handles multi-stage step-up and step-down voltage profiles, real-time curve plotting, and A4 report export in Microsoft Word or Excel.
DJF-1kVA-7.5kV Shielded-Cabin PDIV & PDEV Detector
The DJF-1kVA-7.5kV integrated shielded-cabin PDIV and PDEV detector tests motor windings and insulating materials from AC 500 V to 7.5 kV. It spans 0.1 pC to 10,000 nC with 2% voltage/current accuracy and more than 20 programmable voltage stages. An electric shielding door holds internal cabin background noise at <5 pC.
Oil-Immersed Test Systems with Industrial PC Control
These systems use an oil-immersed test transformer and automatic industrial PC control for programmed voltage ramps and report export. Specify the detector variant when placing an order for a model offering more than one detector.
| System Model | Nominal Capacity / Voltage | Configuration |
|---|---|---|
| DJF-1kVA-5kV | 1 kVA / 5 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-10kVA-50kV (DJF-124-10kVA-50kV) | 10 kVA / 50 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-10kVA-100kV | 10 kVA / 100 kV | Industrial PC, oil-immersed transformer, 124NT PD detector |
| DJF-10kVA-120kV | 10 kVA / 120 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-10kVA-120kV | 10 kVA / 120 kV | Industrial PC, oil-immersed transformer, 124NT PD detector |
| DJF-10kVA-120kV | 10 kVA / 120 kV | Industrial PC, oil-immersed transformer, 125-series PD detector |
| DJF-15kVA-150kV | 15 kVA / 150 kV | Industrial PC, oil-immersed transformer, 125-series PD detector |
| DJF-20kVA-100kV | 20 kVA / 100 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-20kVA-150kV | 20 kVA / 150 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-25kVA-250kV | 25 kVA / 250 kV | Industrial PC, oil-immersed transformer, 126-series PD detector |
| DJF-30kVA-150kV | 30 kVA / 150 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-50kVA-150kV | 50 kVA / 150 kV | Industrial PC, oil-immersed transformer, 125-series PD detector |
| DJF-50kVA-250kV | 50 kVA / 250 kV | Industrial PC, oil-immersed transformer, 124-series PD detector |
| DJF-150kVA-30kV | 150 kVA / 30 kV | Industrial PC, oil-immersed transformer, touchscreen PD detector with model to be confirmed |
| DJF-250kVA-50kV | 250 kVA / 50 kV | Industrial PC, oil-immersed transformer, touchscreen PD detector with model to be confirmed |
Motorized, Gas-Filled and Multichannel Test Systems
| System Model | Nominal Capacity / Voltage | Configuration |
|---|---|---|
| DJF-10kVA-100kV | 10 kVA / 100 kV | Automatic industrial PC control, gas-filled transformer, 124-series PD detector |
| DJF-10kVA-100kV | 10 kVA / 100 kV | Motorized control, oil-immersed transformer, 124T PD detector |
| DJF-124-15kVA-150kV | 15 kVA / 150 kV | Motorized control, oil-immersed transformer, new-style 124 PD detector |
| DJF-124-20kVA-150kV (DJF-20kVA-150kV) | 20 kVA / 150 kV | Fully automatic industrial PC control and touchscreen PD detector. Confirm transformer insulation and detector model. |
| DJF-50kVA-100kV | 50 kVA / 100 kV | AC withstand and partial discharge test system. Confirm controller, transformer insulation and detector. |
| DJF-126-50kVA-200kV | 50 kVA / 200 kV | Four-channel digital PD measurement |
| DJF-124-100kVA-100kV | 100 kVA / 100 kV | Integrated electrical push-button controls and DJF-124 touchscreen PD detector |
| DJF-127-100kVA-100kV | 100 kVA / 100 kV | Integrated electrical push-button controls and DJF-127 touchscreen PD detector |
Confirm the rated test voltage when requesting either 100 kVA model and the available control modes for the two motorized oil-immersed configurations.
Smart Integrated Power-Frequency Test Systems
Use the full DJF model code and configuration when requesting a quote. Some systems share the same kVA and kV ratings but use different controls, transformer insulation or PD detectors.
| System Model | Nominal Capacity / Voltage | Configuration |
|---|---|---|
| DJF-10kVA-100kV | 10 kVA / 100 kV | Smart integrated automatic control with a 10.1-inch touchscreen PD instrument |
| DJF-15kVA-100kV | 15 kVA / 100 kV | Smart integrated automatic control with a 10.1-inch touchscreen PD instrument |
| DJF-30kVA-150kV | 30 kVA / 150 kV | Smart integrated automatic control with a 10.1-inch touchscreen PD instrument |
Shielded-Chamber and PDIV/PDEV Test Systems
The 7.5 kV system measures partial discharge inception and extinction voltages (PDIV and PDEV). It supports programmed voltage stages and hold times within its integrated shielded chamber.
| System Model | Nominal Capacity / Voltage | Configuration |
|---|---|---|
| DJF-1kVA-7.5kV | 1 kVA / 7.5 kV | Automatic industrial PC control, electrically operated shielded chamber and digital PD instrument |
| DJF-124-1kVA-10kV | 1 kVA / 10 kV | Automatic industrial PC control, shielded chamber and 124-series touchscreen PD detector |
| DJF-5kVA-5kV | 5 kVA / 5 kV | Automatic industrial PC control, shielded chamber and touchscreen PD detector |
Test Transformers and Control Consoles
The YDW-30kVA-5kV is a 30 kVA / 5 kV oil-insulated, PD-free power-frequency test transformer. The motorized control console with a new-style 124 PD detector is supporting equipment for a compatible test transformer. For the YDW-50/100 (YDW-50-100) transformer, specify the nameplate rating and matching control package in your inquiry.
When requesting a quotation, provide the system model and configuration, test object and its capacitance, required AC test voltage and hold time, number of measurement channels, and any shielding or PD acceptance requirements.
Comparison: DEMIKS Offline IEC 60270 Systems vs Component & Spot Testers
| Architecture | Voltage Envelope | Output Unit | Primary Engineering Role |
|---|---|---|---|
| DEMIKS DJF-126 / 124 + YDW PD-Free System | AC 0.5 kV to 1000 kV (1–1000 kVA) | Calibrated pC & nC per IEC 60270 | Factory acceptance testing and commissioning of HV transformers, cables, GIS, and motors |
| Low-Voltage Component Hipot + PD Tester (Chroma 19501 class) | AC 0.1 kV to 10 kV | pC / nC | Benchtop optocouplers, relays, and dry components; cannot energize MV/HV power assets |
| Handheld Ultrasonic / Acoustic Camera / TEV Probe (Fluke, EA Technology, Doble survey tools) | Energized line voltage (non-contact) | dBµV / acoustic dB (uncalibrated) | Live walkdowns for external corona and surface tracking; not interchangeable with IEC 60270 FAT |
Traditional modular architectures often source detectors, quadripoles, and high-voltage elements from different vendors. Specify the detector, coupling capacitor and PD-free transformer together so the measurement loop is matched to the test object.
- Simultaneous three-phase and neutral bushing capture on the DJF-126 accelerates transformer partial discharge test and partial discharge detection cycles.
- Partial discharge displays separate discharges in the internal cavity from the external corona.
- Automated voltage ramps capture the inception and extinction of discharge.
Related Cable PD Equipment and Test-Bay Components
A complete test bay may require a separate voltage source and voltage-measurement equipment. Request these in addition to the PD detector to ensure the entire measurement circuit is included in the quotation.
| Model or Product Family | Role in the Test Setup | Selection Boundary |
|---|---|---|
| CBA-6 (confirm order designation) | Cable PD detector specification: compatibility with VLF, power-frequency and series-resonant voltage sources; 0.1 pC PD resolution, 14-bit sampling and Ethernet interface. | Confirm the supplied model designation, voltage-source package and operating limits in the quotation. |
| VLF-PD | Very-low-frequency cable partial discharge test equipment, with PD-Suite software described in the operating manual. | A separate cable PD family. Specify the required test voltage, cable length and cable capacitance; obtain the offered unit's complete rating and configuration. |
| DTC-104D-50kVA + YDW-50kVA-150kV | Intelligent split control console paired with a PD-free test transformer; nominal transformer designation: 50 kVA / 150 kV. | High-voltage excitation equipment. A PD measurement package must be specified separately. |
| RCF-50kV, RCF-100kV, RCF-200kV | AC/DC high-voltage dividers for voltage measurement. | Select the divider for the test voltage and measurement arrangement; these models are not PD detectors. |
| DFY-50kV, DFY-80kV | High-voltage divider designations. | Request the divider ratio, accuracy and AC/DC suitability before specifying either model. |
High-Voltage Test Assets & Insulation Specimens Supported
Early detection of insulation degradation is critical and requires tight tolerance coupling capacitance, filtering, and reactive charging currents. Below are 15 medium-high voltage elements configured by our engineers.
-
1.Liquid-Immersed Power Transformers
Asset Class:35 kV to 500 kV substation & generator step-up unitsDiagnostic Target:Catches pressboard delamination and winding cavity discharge faster than dissolved gas analysis alone.
Circuit Match:DJF-126 4-channel analyzer via bushing tap sensors at 100–500 kHz per IEC 60076-3 and IEEE C57.113.
-
2.Cast-Resin Dry-Type Transformers
Asset Class:6 kV to 35 kV indoor distribution & traction unitsDiagnostic Target:Detects epoxy casting voids where trapped air suffers 2.3× higher electric field stress.
Circuit Match:DJF-124NT or DJF-126 with three-phase PD-free coupling capacitors for ≤10 pC routine acceptance.
-
3.Extruded XLPE Power Cables & Reels
Asset Class:10 kV to 400 kV factory reels & underground circuitsDiagnostic Target:Routine cable pd testing isolates insulation protrusions and voids at <5–10 pC per IEC 60885-3 and IEC 60840.
Circuit Match:DJF-126 (50–500 Hz sync) paired with YDW PD-free transformer or variable-frequency resonant source.
-
4.Cable Terminations & Pre-Molded Joints
Asset Class:15 kV to 220 kV elastomeric & heat-shrink accessoriesDiagnostic Target:In CIGRE's 26,494 km survey, terminations and joints account for most commissioning failures (2.8% and 0.75% vs 0.01% body).
Circuit Match:DJF-124 or DJF-126 with 1000 pF PD-free coupling capacitor and AN quadripole impedance.
-
5.Gas-Insulated Switchgear (GIS) Compartments
Asset Class:72.5 kV to 550 kV SF6 & clean-air GIS baysDiagnostic Target:Flags free metallic particles, shield corona, and epoxy spacer voids prior to grid energization.
Circuit Match:SF6 gas-insulated YDW PD-free transformer (<50°C rise, ≤5 pC) + DJF-127 touchscreen detector.
-
6.Medium-Voltage Metal-Clad Switchgear
Asset Class:3.6 kV to 40.5 kV vacuum breaker panelsDiagnostic Target:Reveals busbar spout tracking and epoxy shrinkage during combined AC hipot and PD tests.
Circuit Match:DJF-125 console with 50 kVA / 100 kV oil-immersed PD-free AC hipot tester and A4 report export.
-
7.High-Voltage Rotating Machine Stator Windings
Asset Class:6 kV to 24 kV hydro, turbo, & industrial electric motor statorsDiagnostic Target:Tracks mica-epoxy groundwall delamination, slot discharge, and grading paint deterioration per IEC 60034-27-1.
Circuit Match:DJF-126 4-channel detector supporting high capacitance loads up to 250 µF.
-
8.EV Hairpin Stators & Inverter-Fed Motor Coils
Asset Class:400 V to 1000 V SiC PWM drive windings (tested up to 7.5 kV AC)Diagnostic Target:Verifies PWM voltage overshoots stay below turn-to-turn enamel PDIV limits per IEC 60034-18-41.
Circuit Match:DJF-1kVA-7.5kV shielded-cabin PDIV/PDEV detector (<5 pC background, >20 programmable stages).
-
9.Instrument Transformers (CT & PT / CVT)
Asset Class:10 kV to 220 kV inductive & capacitive instrument unitsDiagnostic Target:Confirms oil-paper or cast-resin primary insulation health immediately after induced pre-stress.
Circuit Match:DJF-124 touchscreen detector with 9-band interference filtering and independent timer.
-
10.High-Voltage Condenser Bushings
Asset Class:35 kV to 500 kV OIP & RIP transformer bushingsDiagnostic Target:Detects foil-edge partial discharge activity and moisture ingress in 150 pF to 1,200 pF cores.
Circuit Match:DJF-126 at 0.1 pC sensitivity with test-tap quadripole coupling.
-
11.Metal-Oxide Surge Arresters & Varistors
Asset Class:10 kV to 330 kV polymeric & porcelain station arrestersDiagnostic Target:Separates internal radial air-gap micro-discharges from resistive ZnO leakage current.
Circuit Match:DJF-124NT + low-capacitance PD-free transformer (10–30 kVA, ≤5 pC).
-
12.Power Capacitors & Coupling Capacitors
Asset Class:6 kV to 110 kV shunt banks & carrier coupling unitsDiagnostic Target:Verifies film-foil edges remain free of ionization across high capacitance banks up to 250 µF.
Circuit Match:DJF-126 high-attenuation gain gear (-40 dB to 60 dB) with high-current input impedance.
-
13.Epoxy Post Insulators & Vacuum Interrupters
Asset Class:12 kV to 40.5 kV switchgear insulation componentsDiagnostic Target:Screens out micro-cracks around metal inserts that cause flashover in humid service.
Circuit Match:DJF-125 automated console with motorized shielded enclosure (<5 pC).
-
14.Enameled Magnet Wire, Polyimide Films & Potting Resins
Asset Class:AC 500 V to 7.5 kV twisted-pair & sheet dielectric samplesDiagnostic Target:Defines film thickness and resin cure rules needed to insulate traction and aerospace coils.
Circuit Match:DJF-1kVA-7.5kV integrated shielded-cabin PDIV/PDEV tester (6 pF+ specimen support).
15.Custom Multi-Terminal or Ultra-High-Voltage Specimens
Traction transformers, HVDC valve reactors, and submarine cable joints require custom coupling impedances and corona-shielded high-voltage leads. Send your device under test capacitance, test voltage, and target pC limit for a circuit layout within 24 hours.
PD-Free Excitation Sources, Coupling Networks & Signal Conditioning
Contrary to the common assumption that a standalone "<5 pC transformer" guarantees a quiet bay, partial discharge measurements integrate noise across the entire HV loop. A high capacitance DUT can exceed the available current of an undersized source because charging current scales as I = 2πfCV.
"Specimen capacitance from 6 pF bushings to 250 µF stator banks dictates both reactive kVA demand and transformer cooling medium. Remember, a partial discharge test does not replace AC withstand; our YDW series performs a dielectric hipot and <5 pC check simultaneously."
High-Voltage Test Systems Engineering Team, DEMIKS (Shanghai Lingang)Based on specified test voltage, insulated PD-free transformers are either oil-immersed or with SF6 gas, depending on the requirement.
-
Oil-Immersed PD-Free Test Transformer (YDW-Oil)1 kVA to 1000 kVA, AC 0 to 1000 kV; <55°C surface rise; ≤5 pC at rated kVHigh thermal mass for permanent factory bays; heavier floor load than gas cylindersDEMIKS factory-matched
-
SF6 Gas-Insulated PD-Free Transformer (YDW-GTB)1 kVA to 1000 kVA, AC 0 to 1000 kV; <50°C surface rise; ≤5 pC at rated kVLighter crane weight and oil-free cleanliness for GIS halls and mobile trailers; higher unit costDEMIKS factory-matched
-
Coupling Capacitor Network (Ck)500 pF / 1000 pF / 2000 pF, rated up to 1000 kV at ≤2–5 pCLow-inductance path for fast PD pulses; higher Ck/Ca ratio boosts pC sensitivityDEMIKS factory-matched
-
Measuring Impedance Quadripole (AN / Zm)Matched input units for 6 pF to 250 µF specimen capacitanceConverts nanosecond PD current pulses into filtered voltage signals while shunting power currentIncluded with DJF testers
-
Low-Voltage Isolation Filter & Corona RingsMains EMI isolation + spun-aluminum toroidsBlocks workshop VFD harmonics on the LV bus and suppresses air corona on HV leadsIncluded in turnkey bays
-
9-Band Hardware + Digital Bandpass Conditioning10 kHz to 1 MHz digital filter; 9 band combinations; -40 dB to 60 dB gainShifts passband clear of local AM broadcast pickup and thyristor switching spikesBuilt into DJF-124 / 126 / 127
-
Motorized Shielded Test CabinAC 500 V to 7.5 kV (or custom MV enclosure); <5 pC backgroundAvoids full Faraday room construction when testing motor coils and epoxy partsDJF-1kVA-7.5kV integrated
-
Step-Pulse Charge CalibratorDirect pC charge injection across DUT terminals per IEC 60270Locks scale factor before HV energization to compensate capacitive divider attenuationIncluded with DJF testers